中文
CHI 7000

  • CHI 7000 Fire Door

The Guardian™ Fire Door is engineered to meet ever-increasing demands of property owners and insurance underwriters in a simple, easy-to-test, and reset fire protection product. Utilizing standard chain hoist operation, these rolling steel doors feature a reliable, safe procedure for frequent drop testing with a U.L. label rated from 3/4-hour to 4-hour protection. Manual push-up operation, fail-safe, and automatic reset motor operation models are optional to the Guardian standard. The National Fire Protection Association (NFPA) and other model codes recommend frequent drop testing of rolling steel fire doors to ensure a continuous state of operational readiness. C.H.I. strongly promotes these recommendations with the Guardian’s advanced design features.

  • Fire door features

    • Safe, simple, inexpensive, and repeatable drop testing is now made possible in any facility with the flip of a handle
    • No ladders, tools, or equipment are required to drop test and reset Guardian™ Simple Test Fire Doors
    • Installation time is greatly reduced because there is no complicated release and governor assemblies
    • Curtain gauge selection: 22, 20, and 18 gauge galvanized, high tensile steel
    • Slat Profiles: Curved, Flat
    • Operation: Manual push-up, chain hoist (standard) or motor operation
    • Colors: Pre-painted gray, white, tan, and brown or galvanized finish. Powder-coat options available.
    • Guides mount to approved masonry, steel, and sheet rock jambs
    • Options and accessories available

    Fire door curtain

    Slat profile

    flat_slat_images Flat Slat (FS) cover 2-1/2” high by 3/4” deep

    curved_slat_images Curved Slat (CS) cover 2-5/8” high x 7/8” deep

    Endlocks & Windlocks

    • Malleable, zinc-placted cast iron endlocks and windlocks maintain curtain alignment and increase windload capacity. Galvanized malleable cast endlocks are fastened to every other slat. Windlocks are added as dictated by door size & windload requirement.
    • Windload: Designed to withstand a minimum of 20 lbs psf (per sq feet) of windload to an amount that prevents curtain per square foot of windload deflection to prevent buckling or being blown out of the guides.

    endlock

    windlock

    Gauge

    22, 20 or 18 gauge interlocking galvanized steel

    Finish

    • Solid Gray, Gray & White, Tan & White
    • Optional: Stock RAL powder-coat option in 188 colors
    • Slats are hot-dipped galvanized per ASTM A653 A with baked on epoxy primer and polyester finish coat available

    Vision panels

    5" x 1-1/8"

    Fire Door mounting options

    • Face Mount (E or Z) or Jamb Mount
    • Mount to Steel, Wood or Masonry Jambs

    Guides

    • Fabricated from three (minimum 3/16” structural steel angles bolted together to form guide channel.
    • Guide angles include curtain stops & flared guides
    • Hot-dipped or cold sprayed galvanized guides (optional)
    • Upward-expanding guides may be welded to approved steel construction

    Headplates

    • Fabricated from minimum 1/4” steel plate.
    • Drive side of barrel to be provided with precision sealed ball bearing in cast iron housing

    Fire Door operation

    Manual Push-up, Chain-hoist (standard) * Note: Simple test feature not available on manual push-up doors

    Springs

    • Spring tension assembly within barrel by precision ball bearings.
    • Assembly designed for 20,000 cycle life springs (Standard). Higher cycles optional

    Motor operation

    • Rolling Doors are also available with Motor operation.
    • Refer to the motor operator area chart to select operator type based on dimensions and gauge
    • Choose between wall mount or front of headplate mount. Use the charts to determine headroom, sideroom and backroom clearance requirements.
    counterbalance

    Fire door releases

    • 165-degree fusible links provided as standard detection/release devices
    • Fail-safe time delayed releases, smoke detectors and audible and visual warning systems are optional
    • Drop speed is controlled by quiet governor – closing speed is between 6” to 24” per second per NFPA 80

    CHI 7000

    lever

    Optional accessories

    Hood

    CHI hood Fabricated from minimum 24-gauge galvanized steel sheet shaped to fit within the headplates. Intermediate hood support(s) furnished as required.

    Locking

    CHI slide lock Chain hoist doors operated doors furnished with chain hoist keeper suitable for padlocking. Plated slide locks optional.

    To learn more about fire safety standards, please click here.

    Features

    Fire door features

    • Safe, simple, inexpensive, and repeatable drop testing is now made possible in any facility with the flip of a handle
    • No ladders, tools, or equipment are required to drop test and reset Guardian™ Simple Test Fire Doors
    • Installation time is greatly reduced because there is no complicated release and governor assemblies
    • Curtain gauge selection: 22, 20, and 18 gauge galvanized, high tensile steel
    • Slat Profiles: Curved, Flat
    • Operation: Manual push-up, chain hoist (standard) or motor operation
    • Colors: Pre-painted gray, white, tan, and brown or galvanized finish. Powder-coat options available.
    • Guides mount to approved masonry, steel, and sheet rock jambs
    • Options and accessories available

    Curtain

    Fire door curtain

    Slat profile

    flat_slat_images Flat Slat (FS) cover 2-1/2” high by 3/4” deep

    curved_slat_images Curved Slat (CS) cover 2-5/8” high x 7/8” deep

    Endlocks & Windlocks

    • Malleable, zinc-placted cast iron endlocks and windlocks maintain curtain alignment and increase windload capacity. Galvanized malleable cast endlocks are fastened to every other slat. Windlocks are added as dictated by door size & windload requirement.
    • Windload: Designed to withstand a minimum of 20 lbs psf (per sq feet) of windload to an amount that prevents curtain per square foot of windload deflection to prevent buckling or being blown out of the guides.

    endlock

    windlock

    Gauge

    22, 20 or 18 gauge interlocking galvanized steel

    Finish

    • Solid Gray, Gray & White, Tan & White
    • Optional: Stock RAL powder-coat option in 188 colors
    • Slats are hot-dipped galvanized per ASTM A653 A with baked on epoxy primer and polyester finish coat available

    Vision panels

    5" x 1-1/8"

    Mounting options

    Fire Door mounting options

    • Face Mount (E or Z) or Jamb Mount
    • Mount to Steel, Wood or Masonry Jambs

    Guides

    • Fabricated from three (minimum 3/16” structural steel angles bolted together to form guide channel.
    • Guide angles include curtain stops & flared guides
    • Hot-dipped or cold sprayed galvanized guides (optional)
    • Upward-expanding guides may be welded to approved steel construction

    Headplates

    • Fabricated from minimum 1/4” steel plate.
    • Drive side of barrel to be provided with precision sealed ball bearing in cast iron housing

    Operation

    Fire Door operation

    Manual Push-up, Chain-hoist (standard) * Note: Simple test feature not available on manual push-up doors

    Springs

    • Spring tension assembly within barrel by precision ball bearings.
    • Assembly designed for 20,000 cycle life springs (Standard). Higher cycles optional

    Motor operation

    • Rolling Doors are also available with Motor operation.
    • Refer to the motor operator area chart to select operator type based on dimensions and gauge
    • Choose between wall mount or front of headplate mount. Use the charts to determine headroom, sideroom and backroom clearance requirements.
    counterbalance

    Releases

    Fire door releases

    • 165-degree fusible links provided as standard detection/release devices
    • Fail-safe time delayed releases, smoke detectors and audible and visual warning systems are optional
    • Drop speed is controlled by quiet governor – closing speed is between 6” to 24” per second per NFPA 80

    CHI 7000

    lever

    Optional Acc.

    Optional accessories

    Hood

    CHI hood Fabricated from minimum 24-gauge galvanized steel sheet shaped to fit within the headplates. Intermediate hood support(s) furnished as required.

    Locking

    CHI slide lock Chain hoist doors operated doors furnished with chain hoist keeper suitable for padlocking. Plated slide locks optional.

    Fire safety standards

    To learn more about fire safety standards, please click here.


需要了解更多信息吗?

请填写以下表格,免费获取报价或产品相关信息。我们会尽快与您联系。
Invalid Input
Invalid Input
Invalid Input
Invalid Input
Invalid Input
Invalid Input
Invalid Input
中文